EMERSON SE4036P2 Power Supply Module – 24 VDC Redundant Output for DeltaV DCS Systems!

The EMERSON SE4036P2 is a high-reliability, redundant-capable power supply module engineered specifically for the DeltaV™ Distributed Control System (DCS), particularly within the S-Series I/O chassis architecture used across process industries worldwide.

Manufacturer:
Our extensive catalogue, is available now for dispatch to the worldwide.
  • Email: sales@slxytech.com
  • WhatsApp / Wechat:8617062388866
  • Phone:+86 17062388866

Description

The EMERSON SE4036P2 is a high-reliability, redundant-capable power supply module engineered specifically for the DeltaV™ Distributed Control System (DCS), particularly within the S-Series I/O chassis architecture used across process industries worldwide. As a core component of Emerson’s scalable and fault-tolerant control infrastructure, the SE4036P2 delivers stable, regulated 24 VDC power to I/O modules, terminal blocks, and field devices—ensuring uninterrupted operation even during partial system failures or maintenance activities.

Designed for seamless integration into DeltaV S-Series carrier racks (such as those housing SDI, SAI, or SDO modules), the SE4036P2 supports hot-swap functionality, allowing replacement without powering down the entire chassis—a critical feature in continuous processes like refining, chemical production, or biopharmaceutical manufacturing. With a rated output of 360 watts and dual isolated 24 VDC outputs, the SE4036P2 provides ample headroom for densely populated I/O carriers while maintaining tight voltage regulation under dynamic load conditions. Its built-in LED indicators and diagnostic interface feed real-time health data directly into the DeltaV system, enabling predictive maintenance and rapid troubleshooting.

Technical Specifications

Parameter NameParameter Value
Product ModelSE4036P2
ManufacturerEMERSON
Product TypeRedundant DC Power Supply Module for DeltaV DCS
Input Voltage Range85–264 VAC, 47–63 Hz (universal input)
Output VoltageDual isolated 24 VDC ±2%
Maximum Output Power360 W (15 A per channel)
Redundancy SupportYes – parallel operation with other SE4036P2 units (N+1)
Mounting TypePlug-in to DeltaV S-Series I/O carrier chassis
Operating Temperature0°C to +60°C
Cooling MethodConvection cooling (no fan)
Protection FeaturesOver-voltage, over-current, short-circuit, thermal shutdown
CertificationsCE, UL 61010-1, CSA, RoHS compliant

Main Features and Advantages

Hot-Swappable Redundant Architecture: The SE4036P2 enables true zero-downtime power management in DeltaV systems. Multiple units can operate in parallel within the same chassis, sharing load dynamically. If one fails, the others instantly compensate—without disrupting I/O communication or control logic execution.

Integrated System Diagnostics: Unlike generic industrial PSUs, the SE4036P2 communicates its status (input voltage, output current, temperature, fault flags) directly to the DeltaV controller via the backplane. Operators receive alarms for “Power Supply Degraded” or “Over-Temperature” before a failure occurs, significantly reducing mean time to repair (MTTR).

Optimized for Process Industry Reliability: With convection-only cooling (no fans), the SE4036P2 eliminates a common point of mechanical failure, making it ideal for dusty, corrosive, or sterile environments where fan maintenance is impractical. Its wide input range tolerates brownouts and generator switchover transients common in remote plants.

Efficient and Compact: Despite delivering 360W, the SE4036P2 occupies only a single slot in the S-Series chassis, maximizing I/O density. High conversion efficiency (>85%) minimizes wasted heat, reducing HVAC load in control rooms—a key consideration in large-scale deployments.

Seamless DeltaV Ecosystem Integration: From initial configuration in DeltaV Explorer to runtime monitoring in PlantWeb, the SE4036P2 behaves as a native system component—not an external accessory. This simplifies engineering, validation, and compliance with ISA-88/95 standards.

Application Field

The EMERSON SE4036P2 is predominantly deployed in continuous and batch process facilities where power continuity directly impacts safety, product quality, and regulatory compliance. In oil refineries, it powers I/O modules that monitor reactor temperatures, valve positions, and flare gas composition—any interruption could trigger a plant-wide trip. Similarly, in pharmaceutical cleanrooms, the SE4036P2’s fanless design prevents particle generation while ensuring stable power to sensors controlling sterility-critical parameters like differential pressure and humidity.

Chemical plants leverage the SE4036P2’s redundancy in polymerization reactors, where a momentary power glitch could cause runaway reactions. The ability to replace a faulty unit live—without halting exothermic processes—is not just convenient but often mandated by process safety standards (e.g., IEC 61511). In water treatment facilities, the SE4036P2 supports remote pumping stations with unstable grid connections, thanks to its wide AC input tolerance.

Even in hybrid applications like biofuel production or food & beverage lines, the SE4036P2 ensures that analog inputs (e.g., pH, conductivity) and digital outputs (e.g., motor starters) remain energized during utility fluctuations. Across all these sectors, the SE4036P2 acts as the silent enabler of operational resilience—transforming raw electrical power into trusted process integrity.

Related Products

SE4036: Original non-P2 version; functionally similar but lacks enhanced diagnostics and minor firmware improvements
SDI16: 16-channel discrete input module that relies on SE4036P2 for field-side power
SAI16: Analog input module commonly powered via the same chassis as SE4036P2
DeltaV S-Series Carrier Chassis: Hardware platform designed to house SE4036P2 and up to 8 I/O modules
SE4048P2: Higher-power (480W) variant for larger I/O loads or future expansion
DeltaV Power Monitor Card: Optional module that provides granular per-slot current measurement in S-Series racks
AMS Device Manager: Software that can integrate SE4036P2 health data for enterprise-level asset performance management

Installation and Maintenance

Pre-installation preparation: Before inserting the SE4036P2 into a DeltaV S-Series carrier, confirm that the chassis backplane firmware supports this hardware revision. Ensure the AC input circuit is de-energized or that redundant units are already active if performing a live swap. Align the module carefully with the guide rails—forcing insertion may damage backplane pins. Verify that adjacent slots are not obstructing airflow, even though the unit is fanless, as convection requires minimal clearance.

Maintenance recommendations: Monitor the SE4036P2’s status LEDs: green = normal, red = fault. Use DeltaV Diagnostics to check output current trends—gradual increases may indicate failing field devices drawing excess current. Perform annual infrared thermography on the power terminals to detect loose connections. Keep spare SE4036P2 units in climate-controlled storage to preserve capacitor lifespan. Always replace in pairs when operating in redundant mode to avoid age mismatch and uneven load sharing.