Multilin MM2-PD-1-2-120 | Advanced Motor Protection & Control Relay

The GE Multilin MM2-PD-1-2-120 is a compact, intelligent motor management relay designed to protect, monitor, and control low- to medium-voltage three-phase induction motors in industrial and utility environments. Part of General Electric’s (now part of GE Vernova) widely deployed Multilin MM2 series, this relay provides comprehensive protection against electrical faults—including overload, phase imbalance, phase loss, under/overvoltage, ground fault, and stall conditions—while also offering metering, event recording, and remote communication capabilities.

Manufacturer:
Part number: MULTILIN MM2-PD-1-2-120
Our extensive catalogue, including : MULTILIN MM2-PD-1-2-120 , is available now for dispatch to the worldwide.
  • Email: sales@slxytech.com
  • WhatsApp / Wechat:8617062388866
  • Phone:+86 17062388866

Description

The GE Multilin MM2-PD-1-2-120 is a compact, intelligent motor management relay designed to protect, monitor, and control low- to medium-voltage three-phase induction motors in industrial and utility environments. Part of General Electric’s (now part of GE Vernova) widely deployed Multilin MM2 series, this relay provides comprehensive protection against electrical faults—including overload, phase imbalance, phase loss, under/overvoltage, ground fault, and stall conditions—while also offering metering, event recording, and remote communication capabilities.

The model suffix “PD-1-2-120” indicates key specifications:

  • P: Protection + Control functionality

  • D: Includes digital inputs/outputs

  • 1: 1 current input channel (typically for ground fault via residual or core-balance CT)

  • 2: 2 Form-C programmable output contacts

  • 120: Operates on 120 VAC auxiliary power

Housed in a rugged, DIN-rail mountable enclosure, the MM2-PD-1-2-120 is ideal for protecting critical assets such as pumps, fans, compressors, mixers, and conveyors in water/wastewater plants, oil & gas facilities, mining operations, and manufacturing lines. Its intuitive front-panel interface allows local configuration and real-time status viewing, while optional communication modules (e.g., Modbus RTU) enable integration into SCADA and asset management systems.

Technical Specifications

Parameter NameParameter Value
ModelMM2-PD-1-2-120
ManufacturerGE Multilin (GE Vernova)
FunctionMotor protection, monitoring, and control
Auxiliary Power120 VAC ±15%, 50/60 Hz
Current Inputs3-phase phase currents (via external CTs); 1 ground fault input (residual or sensitive)
Voltage InputsOptional (requires external VTs; not standard on base model)
Digital Inputs2 programmable (for start/stop, remote trip, etc.)
Relay Outputs2 Form-C (SPDT) programmable contacts (rated 5 A @ 250 VAC)
Protection FunctionsOverload (thermal model), phase imbalance, phase loss, under/overvoltage, ground fault, stall, jam, undercurrent
CommunicationOptional RS485 Modbus RTU (via add-on module or specific variant)
MountingStandard 35 mm DIN rail
Operating Temperature-20°C to +70°C
Standards ComplianceIEC 60255, IEEE C37.96, UL 508, CSA C22.2

Main Features and Advantages

Advanced thermal overload modeling: The MM2-PD-1-2-120 uses a precise thermal replica algorithm that accurately simulates motor heating and cooling—preventing nuisance trips during startup while ensuring protection during sustained overloads.

Integrated ground fault detection: With a dedicated ground fault input (supporting both residual and core-balance CTs), the relay detects low-level ground faults (<300>

Programmable logic & automation: Built-in control logic allows the relay to manage motor start/stop sequences, interlocks, and alarm annunciation without external PLCs—reducing system complexity and cost.

Event & disturbance recording: Captures up to 100 events with timestamps, including trip causes, current/voltage snapshots, and contact status—accelerating root-cause analysis after failures.

Compact & cost-effective: Combines protection, control, and monitoring in a single, space-saving device—ideal for retrofitting legacy motor starters or new panel builds with budget constraints.

Application Field

The GE Multilin MM2-PD-1-2-120 is extensively used across industries where motor reliability directly impacts operational continuity:

  • Water & Wastewater: Protects submersible pumps, lift stations, and aeration blowers from dry-run, clogging, or voltage sags.

  • Oil & Gas: Safeguards injection pumps, glycol dehydrators, and compressor motors in remote or hazardous locations.

  • Mining & Metals: Controls conveyor drives and crusher motors exposed to dust, vibration, and frequent starts.

  • Power Generation: Monitors auxiliary motors in balance-of-plant systems (e.g., cooling tower fans, lube oil pumps).

  • Manufacturing: Ensures uptime for production line motors by preventing damage from mechanical jams or phase imbalances.

Related Products

  • MM2-PD-1-2-240: Identical functionality but powered by 240 VAC

  • MM2-PD-1-4-120: Same as above but with 4 output contacts

  • MM300 / MM400: Higher-end Multilin relays with full voltage inputs, advanced communications (Ethernet, DNP3), and arc flash detection

  • F650 Feeder Management Relay: For switchgear and distribution feeder protection

  • CTs (e.g., GE CLS series): Required current transformers for phase and ground fault sensing

  • Modbus RTU Communication Module: Enables SCADA integration (may be built-in on certain MM2 variants)

  • Motor Control Center (MCC) Buckets: Common installation location for MM2 relays

Installation and Maintenance

Installation Tips:

  • Mount on a standard 35 mm DIN rail in a clean, ventilated enclosure.

  • Use shielded twisted-pair cables for CT secondary wiring; ground shield at relay end only.

  • Ensure auxiliary 120 VAC supply is stable and protected by a fuse or breaker.

  • Configure motor nameplate data (FLA, service factor, restart inhibit time) during commissioning using front keypad.

Maintenance Recommendations:

  • Periodically verify settings against motor specifications.

  • Test ground fault function annually using a primary or secondary injection test set.

  • Review event logs after any process upset to detect early warning signs (e.g., repeated phase imbalance).

  • Keep firmware updated if communication features are used (though base MM2 models typically have fixed firmware).